Contact

Data sheets

Waste Water Results


Concentration Of Element In Waste Water After Paint Exposure To EFS-2500,
Reported In Parts Per Billion

Elements Control 1 Day 2 Day 3 Day GVRD Maximum
Ag 0.18 .032 0.14 6.30 1000
Al 3.57 9.87 14.14 3.15 50000
As 0.00 0.00 0.00 0.00 NA
Ba 17.42 94.21 42.39 26.82 NA
Cd 4.27 17.40 1.98 8.06 200
Co 0.00 0.05 0.00 0.32 5000
Cr 8.93 262.10 203.80 114.63 4000
Cu 16.77 28.80 16.89 17.66 2000
Fe 0.00 0.00 0.00 0.00 10000
Mg 286.80 227.30 170.80 141.54 NA
Mn 1.31 0.89 0.70 0.27 5000
Mo 0.32 0.42 0.41 1.92 1000
Ni 0.00 0.00 0.00 0.00 2000
P 2.29 15.91 20.60 6.76 NA
Pb 0.89 17.40 2.73 4.86 4000
Sn 4.79 1.17 2.76 2.30 NA
Sr 6124.00 30180.00 9413.00 5026.94 NA
Ti 0.00 0.00 0.00 0.00 NA
V 0.00 0.00 0.00 0.00 NA
Zn 63.78 61.01 37.19 44.47 3000
Zr 0.20 0.13 0.21 0.08 NA